3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor

Detail produk:

Tempat asal: Cina
Nama merek: TIAN RUI
Sertifikasi: ROHS REACH
Nomor model: 3RB-8

Syarat-syarat pembayaran & pengiriman:

Kuantitas min Order: 1000 pcs
Harga: Negotiable
Kemasan rincian: 1000 pcs / tas PE
Waktu pengiriman: 5-7 hari
Syarat-syarat pembayaran: D / P, T / T, Paypal, Western Union
Menyediakan kemampuan: 1000000 + PCS + Bulan
Harga terbaik Kontak

Informasi Detail

Nama Produk: Tabung Pelepasan Gas 3RB-8 Aplikasi: Peralatan CATV, Jalur data, dll
Arus Impuls 8/20μ: 10KA Tegangan DC Spark-over: 75V-800V
Jenis timah: SMD atau DIP Kapasitansi sangat rendah: Maks 1.5pF
Ukuran: 8mm * 10mm Fitur: Tegangan tembus stabil
Pengobatan permukaan: Berlapis Nikel atau Berlapis Timah
Cahaya Tinggi:

Tabung Pelepasan Gas 75V

,

Tabung Pelepasan Gas Pelindung Surge 1.5pF

,

Tabung GDT 10KA

Deskripsi Produk

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor

 

Deskripsi 3RB-8 3R 10KA 1.5pF 75V-800V Surge Protector Arrester Gas Discharge Tube GDT

 

GDT ditempatkan di depan, dan paralel dengan, peralatan telekomunikasi sensitif seperti saluran listrik, saluran komunikasi, saluran sinyal dan saluran transmisi data untuk membantu melindunginya dari kerusakan yang disebabkan oleh tegangan lonjakan transien yang mungkin diakibatkan oleh sambaran petir dan operasi switching peralatan .Perangkat ini tidak mempengaruhi sinyal dalam operasi normal.Namun, jika terjadi lonjakan tegangan lebih, seperti sambaran petir, GDT beralih ke keadaan impedansi rendah dan mengalihkan energi dari peralatan sensitif.

 

GDT kami menawarkan perlindungan lonjakan tingkat tinggi, rentang tegangan yang luas, kapasitansi rendah, dan banyak faktor bentuk termasuk perangkat pemasangan permukaan baru, yang membuatnya cocok untuk aplikasi seperti modul Main Distribution Frame (MDF), aplikasi telekomunikasi berkecepatan data tinggi (misalnya
ADSL, VDSL), dan perlindungan lonjakan arus pada saluran listrik.Kapasitansinya yang rendah juga menghasilkan distorsi sinyal yang lebih sedikit.Ketika digunakan dalam solusi perlindungan sirkuit terkoordinasi dengan perangkat PolySwitch, mereka dapat membantu produsen peralatan memenuhi standar peraturan keselamatan yang ketat.

 

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 0

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 1

 

Fitur 3RB-8 3R 10KA 1.5pF 75V-800V Surge Protector Arrester Tabung Pelepasan Gas GDT

 

• Respons yang sangat baik terhadap transien yang meningkat cepat
• Tegangan tembus stabil
• frekuensi kerja GHz
• Kemampuan arus impuls 8/20μs: 10KA
• Non-Radioaktif
• Kapasitansi Ultra Rendah (<1.5pF)
• Resistansi isolasi tinggi
• Sesuai dengan bebas timah
• Sesuai dengan RoHS dan REACH
• UL 497B Diakui: E465335
• Ukuran: 8mm * 10mm
• Penyimpanan dan suhu operasional: -40~+90°C

 

Aplikasi dari 3RB-8 3R 10KA 1.5pF 75V-800V Surge Protector Arrester Tabung Pelepasan Gas GDT

 

• Peralatan komunikasi
• Peralatan CATV
• Jalur data
• Catu daya
• Perlindungan SLIC Telekomunikasi
• Peralatan pita lebar

• Peralatan ADSL, termasuk ADSL2+
• Peralatan XDSL
• Peralatan satelit dan CATV
• Peralatan uji
• Elektronik konsumen

 

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 2

 

Karakteristik listrikdari 3RB-8 3R 10KA 1.5pF 75V-800V Surge Protector Arrester Tabung Pelepasan Gas GDT

 

Nomor Bagian DC
Tegangan Spark-over1) 2) 3)@100V/S
Tegangan Percikan Impuls3) Resistansi Isolasi
4)
Kapasitansi @1MHz Peringkat Kehidupan
Arus Pelepasan Impuls
@8/20μs5)
AC
Arus Debit @50Hz 1S5)
Kehidupan Impuls @10/1000μS 200A5)
100V/μS 1KV/μS
Maks Maks min Maks Nominal
±5 kali
Maks 1 kali Nominal 5 kali min
MENCELUPKAN SMK DIP-F DIP-T V V V G pF KA KA A Waktu

3R075

TB-8

3R075S

B-8

3R075

TB-8F

3R075

TB-8T

75±20% 500 600 1 1.5 10 20 10 300
3R090TB-8 3R090SB-8 3R090TB-8F 3R090TB-8T 90±20% 500 600 1 1.5 10 20 10 300
3R150TB-8 3R150SB-8 3R150TB-8F 3R150TB-8T 150±20% 500 600 1 1.5 10 20 10 300
3R200TB-8 3R200SB-8 3R200TB-8F 3R200TB-8T 200±20% 600 700 1 1.5 10 20 10 300
3R230TB-8 3R230SB-8 3R230TB-8F 3R230TB-8T 230±20% 600 700 1 1.5 10 20 10 300
3R250TB-8 3R250SB-8 3R250TB-8F 3R250TB-8T 250±20% 600 700 1 1.5 10 20 10 300
3R350TB-8 3R350SB-8 3R350TB-8F 3R350TB-8T 350±20% 800 900 1 1.5 10 20 10 300
3R400TB-8 3R400SB-8 3R400TB-8F 3R400TB-8T 400±20% 850 950 1 1.5 10 20 10 300
3R420TB-8 3R420SB-8 3R420TB-8F 3R420TB-8T 420±20% 850 950 1 1.5 10 20 10 300
3R470TB-8 3R470SB-8 3R470TB-8F 3R470TB-8T 470±20% 900 1000 1 1.5 10 20 10 300
3R600TB-8 3R600SB-8 3R600TB-8F 3R600TB-8T 600±20% 1100 1200 1 1.5 10 20 10 300
3R800TB-8 3R800SB-8 3R800TB-8F 3R800TB-8T 800±20% 1400 1500 1 1.5 10 20 10 300
Tegangan Cahaya pada 10mA.................................................. ......................... ~60V
Tegangan Busur pada 1A ~ 10V
Transisi Cahaya ke Arc Arus………………………………………….. ~1A
Suhu operasi dan penyimpanan………………………………..….. -40~+90°C
Kategori iklim (IEC60068-1)……………………………………….. 40/90/21
Bobot…………………………………………………………………….MENCELUPKAN
SMD DIP-F
DIP-T
~ 2.10g
~1.85g
~ 2.35g
~ 2.15g
Pengobatan permukaan………………………………………….....………….DIP -Berlapis Nikel
SMD -Berlapis matte-timah
1)Saat pengiriman AQL 0.65 level II, DIN ISO 2859
2)Dalam mode terionisasi
3)Ujung atau cincin elektroda ke elektroda pusat
4)Tegangan Pengukuran Resistansi Isolasi:
75V pada DC 25V
90V~150V pada DC 50V
Lainnya di DC 100V
5)Arus total melalui elektroda pusat, setengah nilai melalui ujung masing-masing elektroda cincin.Persyaratan sesuai dengan ITU-T Rec.K.12, IEC 61643-311, GB/T 9043.


3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 3

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 4

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 5

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 6

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 7

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 8

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 9

 

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 10

 

Parameter Solder - Solder gelombang (Perangkat Melalui Lubang)

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 11

Kondisi Solder Gelombang Perakitan bebas Pb
Memanaskan lebih dulu Suhu Min 100 °C
Suhu Maks 150 °C
Waktu (Min ke Maks) 60-180 Detik
Suhu Solder Pot 280 °C Maks
Waktu Tinggal Solder 2-5 Detik

 

 

Parameter Solder - Solder Reflow (Perangkat Pemasangan Permukaan)

3RB-8 Seri 3R 10KA 1.5pF Surge Protector Tabung Pelepasan Gas GDT Arrester 75V-800V Arrestor 12

Kondisi aliran ulang Pb - Gratis
perakitan
Memanaskan lebih dulu -Suhu Min (Ts(mnt)) 150 °C
-Suhu Maks (Ts (maks)) 200 °C
- Waktu (min ke maks) (ts) 60 -180 Detik
Tingkat kenaikan rata-rata (Suhu CairTL) ke puncak Maks 3°C/detik
TS (maks)ke TL - Tingkat Peningkatan 5°C/detik maks
Arus kembali - Suhu (TL)(Cairan) 217°C
- Waktu (min ke maks) (ts) 60 -150 Detik
Suhu Puncak (TP) 260 +0/-5°C
Waktu dalam 5 ° C dari puncak sebenarnyaSuhu (tp) 10 - 30 Detik
Tingkat Ramp-down 6°C/detik maks
Waktu 25 ° C ke Suhu puncak (TP) 8 menit Maks
Tidak melebihi 260 °C

 

 


 

 
 